Metering CI Solar Supplies Co.
Online Catalog

 
Power Tracer
V, A, kVA, kVAR, kWh, PF and THD recording for single, split and three-phase loads. 
Measurements in any combination of: average, instantaneous, minimum, and/or maximum  instantaneous waveform viewing, 128K of memory (~30,000 records) Long-life battery power – no cords to plug-in.
Total package includes: The Power Tracer™, software, a null modem cable, voltage leads, a pre-installed lithium battery, a 9 Volt wall transformer and manual. Current transducers are available in 15, 70 and 150 Amp sizes and must be purchased separately.
Model No. Description Price Qty 2 Qty 6
PR/TE-PWR-TRCR Recording Poly Phase Power Meter for Assisting the Professional Power System Designer. Measures, Calculates and Records V, A, kVA, kW, VARS, PF & THD Over Time. $1240.00 1054.00 930.00
PR/TE-CT15 15 Amp Split Core Current Transducer $110.00 93.50 82.50
PR/TE-CT70 70 Amp Split Core Current Transducer $110.00 93.50 82.50
PR/TE-CT150 150 Amp Clamp-On Current Transducer $280.00 238.00 210.00

 
Line Logger
This power measurement device is designed to plug right into a wall socket and measure a        specific load (or combination of loads) power consumption. The Line Logger will display
Volts and Watts, and will record cumulative kWh.

           

           

Model No. Description Price Qty 2 Qty 6
PR/TE-LN-LGGR Line Logger Measures Instantaneous Volts, Watts & Records Cumulative kWh for Loads Operating on Standard 120 VAC Wall Outlets. $370.00 314.50 277.50

 
TM500 System Monitor
Complete with Digital Read Out, Recharge Reminder, Low Voltage Indicator, 12/24 Volt Shunt, and plug-in Shunt Communication Cable.
Simply mount your meter, connect the shunt to your battery terminals,
and plug in the communication cable. Battery Voltage: 8 to 32 VDC or to 70 Volts DC with optional 48 VDC adapter. Net Battery Current: 0.1 to 999 Amps. DC Battery Charge Level: 5% increments. Cumulative Amp Hours: Monitors battery bank use and provides estimated battery life information. Days since Full: Days since the battery bank was fully charged -- encourages proper battery management by indicating system problems. 
Battery Highest Voltage: Resetable, monitors charge controllers and battery chargers. Battery Lowest Voltage: Resetable, monitors system to detect malfunction or system failure. 
Model No. Description Price Qty 2 Qty 6
PR/TE-TM500-NS Amp/Hr Voltage System Meter. No Shunt. (Requires 500A/50 mv Deltec Shunt) for 12,24,& 48Volt DC Systems(48V Requires TM48)  $195.00 165.75 146.25
PR/TE-TM500 Amp/Hr Voltage System Meter. Incl. Shunt for 12,24, & 48Volt DC Systems
(48V Requires TM 48)
$245.00 208.25 183.75
PR/TE-TM48 48 VDC Adapter for TM500 & TM500-NS $40.00 34.00 30.00

 
Omnimeter+ Digital Meter
Information can be displayed as percent, bar-graph, or numeric values. Records and graphs energy data. The plus + in Omnimeter's name indicates a new model with many improvements and changes. The meter now uses negative shunts, functions from 7 to 100VDC, has a brighter supertwist backlit LCD, comes with 32K Ram standard, does 4 simultaneous channels of (with OmniLink), has non-volatile memory (won't lose settings when depowered) and will automatically boot and reconfigure after power surge or disconnect. Measures volts, amps, amp-hours and kWH on up to 4 separate channels. Simple menu operation, programs for use with any shunt and measures up to 1100 Amps DC. Automatically determines battery capacity. Can be used to control a two wire remote start generator. OmniCharge feature includes menu driven dual channel  charge control software at no extra cost. Order a mercury contactor and/or a PWM-15 or PWM-30 to provide charge control. OmniLink+ Software allows remote access and control through the optional battery powered internal modem and phone line or links directly to your IBM compatible computer with standard PC type plug in connector for comm port. Settings and data logging functions can be set remotely as 4 simultaneous data logs. A data log is a recording of selected values at a selected time interval, i.e. battery voltage, charging current, and/or load current. OmniLarm Software enables your omnimeter to call you through a modem to your PC when any of the programmable alarms are activated. An alarm message is then displayed on your screen automatically. Includes 18 programmable alarms (2 available for external inputs such as security, water level, smoke alarm etc. Dim.5.25" x 6.5" x 2". Limited one year warranty. 
Model No. Description Price  Qty 2 Qty 6
PR/SS-OMNI+ Omnimeter 7-100 VDC w/32K Ram $360.00 306.00 270.00
PR/SS-OMNI+M Omnimeter 7-100 VDC w/32K Ram and Integrated Modem $495.00 420.75 371.25
PR/SS-PWM-15 15A Pulse Width Modulated Charge Control for Omnimeter $144.30 122.65 108.25
PR/SS-PWM-30 30A Pulse Width Modulated Charge Control for Omnimeter $323.40 274.90 242.55
PR/SS-OMNILINK+ PC Compatible Software w/data graphing & logging $93.00 79.05 69.75
PR/SS-OMNILARM Alarm Response Software $55.00 46.75 41.25
PR/DT-SHNT100A 100A/100mV Shunt $25.00 21.25 18.75
PR/DT-WB-500-100 500A/100mV Shunt $30.00 25.50 22.50
Mercury Contactor Relays
Use these contactors to control large currents with mA relay closures. NC models work with Omnicharge. NO models can be used for other purposes.
Model No. Voltage Current Coil Current Description Price Qty 2 Qty 6
PR/SS-MC35-12NO 12 35A 0.33 Normally Open Mercury Contactor $58.20 49.50 43.65
PR/SS-MC35-24NO 24 35A 0.33 Normally Open Mercury Contactor $58.20 49.50 43.65
PR/SS-MC35-24NC 24 35A 0.33 Normally Closed Mercury Contactor $58.20 49.50 43.65
Trimetric Meter Digital System Monitor
For 12, 24 or 48 (see option for 48) volt systems includes displays for Amp-Hours, Amps, Volts (8-35V) and also includes some unique features not available on other AH meters: · Settings are not lost when power is disconnected. · AH can be reset manually, or when your programmed full charge settings are reached. · Reached Charge LED lights when batteries have reached a full charge and will stay lit until manually reset.· Charging LED indicates batteries are currently under charge (even when the amps display is not selected). · Highly visible LED display can easily be turned off to save power. Uses standard 500A/50mV or 100A/100mV shunts (not included). Voltage is displayed to tenths of a volt. Amperage to above 500A, Amp-Hours are displayed to a maximum of 999,000. User settings for full charge parameters, amp-hour capacity, and charge efficiency. Seven Advanced Features ·Hours since last full charge, ·amp-hours removed since last full charge, ·total amp-hours discharged in lifeof  battery, ·charge efficiency of last battery cycle, ·deepest discharge in AH (individual reset), ·maximum and minimum battery voltage reached (individual reset), and ·adjustable smoothing of current charged parameter (improves accuracy for cycling type of charge regulators). No load current 20mA. The TM-1 model comes with a metallic box attached to the back with four screws and nuts. The TM-2 model is attached to a plate which allows mounting to a standard double electrical box. Limited1 year warranty. 
Model No. Description Price Qty 2 Qty 6
PR/BE-TM-2020 Trimetric Meter for 12 or 24V Larger Display,AH in % $175.00 148.75 131.25
PR/BE-TM-1 Trimetric Meter for 12or 24V with metal box back $175.00 148.75 131.25
PR/BE-TM-2 Trimetric Meter for 12 or 24V on mounting plate $175.00 148.75 131.25
PR/BE-48 Add-on for conversion to 48 V, includes surge protection $29.00 24.65 21.75
PR/DT-SHNT-100A 100A/100mV Shunt $25.00 21.25 18.75
PR/DT-SHNT-500A 500A/50mV Shunt $29.00 24.65 21.75
WR/BE-18-3PR 18 ga. 3 pair twisted cable (priced per foot) $0.60 0.50 0.45

 
MARK 3 LCD Digital Display
For use on 12 to 48 VDC systems. A four position rotary switch selects between 2 voltage and 2 current readings. Aux. voltage position can be used for array voltage, secondary battery voltage, alarm setpoints display(field adjustable), or may be programed for use with a 100A shunt for an additional current reading. Current 1 comes with a built-in 30A shunt.You may add a shunt for up to 2000 Amps for current 2. Programmable LED alarm setpoints for low and high voltage. Uses 18 mA (23 with alarm on). Accessories for alarm relay closures and beepers also available. 
Model No. Description Price Qty 2 Qty 6
PR/SC-DM3-12-48 12-48 VDC Digital Volt-Amp Meter $148.50 126.25 111.40
PR/DT-SHNT-100A 100 Amp /100mV Shunt $25.00 21.25 18.75
PR/DT-SHNT-500A 500 Amp /50mV Shunt $29.00 24.65 21.75
PR/SC-BOX4X7 Surface mount box forNew DM3 $27.00 22.95 20.25

CI Solar Supplies Co, PO Box 2805, Chino, CA 91710  (909) 628-6440
jclothi@attglobal.net